779443-01 -
NI
The PCI-6520 is an industrial digital I/O module with high channel isolation and industry-standard 24 V logic levels. For added safety the PCI-6520 requires a keyed connector. If a computer or application fault occurs, the PCI-6520 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. It also features programmable power-up states, digital filtering, and change detection for optimal control over your application.
-
40-780A-522 -
Pickering Interfaces Ltd.
This PXI microwave module is part of a range that gives you the highest RF & microwave switching performance available. Applications are mainly in the microwave region, however there are many uses in the RF spectrum where extremely low insertion loss and ultra high isolation are critical, they may also be used for lower frequency RF applications where power handling to 240W is required (700W for N-Type options).
-
PXI-7901 -
ADLINK Technology Inc.
ADLINK PXI-7901 is a general-purpose (GP) switch module implementing 16-CH independent single-pole double-throw (SPDT) relays (1 Form C). PXI-7901 can connect one input to one output and be used as signal switching and routing for measurement system or ATE. Thanks to its high switching capacity, PXI-7901 can also be used to turn on or turn off devices such as motors, fans, heaters, and lights. The contact position of the relays can be changed either by direct software commands or by following the instructions previously stored in the on-board scan list. The scan list advances upon the trigger from external measurement devices, such as a DMM. The scan list could also advance when the scan-delay timer expires. In the PXI-7901, PXI trigger functions are supported and software programmable. Multiple modules can therefore be synchronized without additional field wiring.
-
40-161A-102 -
Pickering Interfaces Ltd.
The 40/42-161A-102 is a PXI/PXIe 6xSPDT power relay module and is part of a range of high density power switching solutions with a choice of SPST, and SPDT relay configurations with or without hardware interlock. Electro-mechanical power relays are used wich are suitable for switching loads up to 16 A at 250 VAC.
-
42-161A-102 -
Pickering Interfaces Ltd.
The 40/42-161A-102 is a PXI/PXIe 6xSPDT power relay module and is part of a range of high density power switching solutions with a choice of SPST, and SPDT relay configurations with or without hardware interlock.
-
781421-15 -
NI
4x86, 0.3 A, No Row Access, Reed Matrix Module for SwitchBlock - The SWB‑2815 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
781420-15 -
NI
4x86, 0.3 A, Row Access, Reed Matrix Module for SwitchBlock - The SWB‑2815 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
781421-10 -
NI
4x43, 1 A, No Row Access, Reed Matrix Module for SwitchBlock - The SWB‑2810 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
781420-10 -
NI
4x43, 1 A, Row Access, Reed Matrix Module for SwitchBlock - The SWB‑2810 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
40-136-011 -
Pickering Interfaces Ltd.
Pickering Interfaces 40-136 Power Reed Relay Modules are suitable for applications where ordinary reed relay modules require additional current/voltage capacity. The 40-136 is suitable for voltages to 200V and current to 2.5A. Available in Normally Open (SPST & DPST) configurations. Connections are made via a front panel mounted 50 or 78-pin D-Type connector.
-
40-310-101 -
Pickering Interfaces Ltd.
The 40-310/320 Range of High Voltage Switching Modules will hot switch up to 750V peak and cold switch up to 1000V peak in either general purpose relay (40-310) or multiplexer (40-320) configurations. These modules contain high-quality reed relays with switching ratings comfortably higher than the 40-310/320 specification. Applications for the 40-310/320 series modules include; circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing.
-
40-136-111 -
Pickering Interfaces Ltd.
Pickering Interfaces 40-136 Power Reed Relay Modules are suitable for applications where ordinary reed relay modules require additional current/voltage capacity. The 40-136 is suitable for voltages to 200V and current to 2.5A. Available in Normally Open (SPST & DPST) configurations. Connections are made via a front panel mounted 50 or 78-pin D-Type connector.
-
40-411-001 -
Pickering Interfaces Ltd.
The 40-411 is the perfect solution for driving external relays from a PXI system or from Pickering Interfaces LXI modular chassis. Each module provides 64 channels of low side switching for external relays. Users need to simply connect a positive voltage source to one side of the relay coil and the other side to the 40-411 output. Each output is capable of sinking up to 1 Amp of continuous current.
-
65-223-102 -
Pickering Interfaces Ltd.
The range includes four plug-in models covering matrices of up to 1,536x4 in increments of 128 (model 65-221), 768x8 in increments of 64 (model 65-223), 384x16 in increments of 32 (model 65-225), and 192x32 in increments of 32 (model 65-227). Users can specify as many or as few plug-in modules (up to six) required and can field upgrade the chassis to extend the matrix when necessary. Another important feature is that over 1,500 relays can be closed simultaneously for specific conditions for parametric testing.
-
65-227-101 -
Pickering Interfaces Ltd.
The range includes four plug-in models covering matrices of up to 1,536x4 in increments of 128 (model 65-221), 768x8 in increments of 64 (model 65-223), 384x16 in increments of 32 (model 65-225), and 192x32 in increments of 32 (model 65-227). Users can specify as many or as few plug-in modules (up to six) required and can field upgrade the chassis to extend the matrix when necessary. Another important feature is that over 1,500 relays can be closed simultaneously for specific conditions for parametric testing.